4 – Interactive Commands
Diagnostics Menu (Command Line Options -kl, -kr, and -dm)
SN0054614-00 F 4-71
A
v1.x.x Build x
Warning: The Diagnostic Loopback and Read/Write Buffer Tests require that the
HBA has no outstanding input and output operations. Please make sure there is
no active I/O before starting the test(s).
Do you want to proceed with the test(s)?
1: Yes
2: No
Note: 0 to return to Main Menu
Enter Selection: 1
-------------------------------------------------------------------
HBA 1: QEM2462 Port 1 WWPN xx-xx-xx-xx-xx-xx-xx-xx Port ID 02-0E-00
------------------
Test Configuration
------------------
Data Pattern : Random
Data Size (Bytes) : 512
Number of test(s)(1-65535) : 500
Test Increment(1-65535) : 1
On Error : Ignore
Test Continuous : OFF
--------------------------------------------------------------
Diagnostics - Loopback Test Result
----------------------------------
Note: Press <Enter> to stop the test any time
---------------------------------------------
HBA Test Data Pattern Status CRC Disparity FrameLength Active
--- ----------------------- ------ ---- --------- ----------- ------
1 B4-31-0E-AA-AD-CF-D5-B0 Success 0 0 0 \
4.12.2.2
Run Read/Write Buffer Test
When you select Start Diagnostics Test for the read/write buffer test, the
following is returned (example):
------------------------------------------------------------------------------
HBA Instance 4: QLE2562 Port 2 WWPN 21-01-00-1B-32-36-18-EE PortID 01-0F-00
------------------------------------------------------------------------------
------------------
Test Configuration
------------------
Data Pattern : Random
Data Size (Bytes) : 128
Number of test(s)(1-10000) : 10000
Test Increment(1-10000) : 1