Q-Logic FC HBA CLI Network Card User Manual


 
B – XML Format 2
Display System Information (Command Line Option -g)
SN0054614-00 F B-15
A
Vendor="value"
Product="value"
Revision="value"
Size="value"
Type="value" />
</Target>
</HBA>
<Status> n </Status>
<Reboot> n /Reboot>
</QLogic>
The <Target> sequence repeats for each LUN attached to the target. The LUN
list is listed under the target, not under the adapter.
B.8.5
Selective LUNs
(Command Line Option -m)
The command format is:
scli -m all (view | ?) -x2
The XML Format 2 for the selective LUNs information is as follows:
<?xml version="value" encoding="value"?>
<QLogic>
<AppName>SANsurfer FC HBA CLI</AppName>
<AppVersion>vn.n.nn Build nn</AppVersion
<AppXmlVersion>n.nn</AppXmlVersion>
<HBA>
<HBA Instance="value" HBAModel="value" HBAPort="value"
WWNN="value" WWPN="value" />
<Target>
<WWNN> Target WWNN </WWNN>
<WWPN> Target WWPN </WWPN>
<EnabledLUN ID="value" LUNWWNN="value" LUNWWPN="value"/>
</Target>
</HBA>
<Status> n </Status>
<Reboot> n /Reboot>
</QLogic>
The <Target> </Target> sequence repeats for each enabled LUN on the
target.
B.8.6
Target Persistent Binding
(Command Line Option -p)
The command format is: