Q-Logic FC HBA CLI Network Card User Manual


 
4 – Interactive Commands
Diagnostics Menu (Command Line Options -kl, -kr, and -dm)
4-74 SN0054614-00 F
S
BR, max: 0x00
BR, min: 0x00
Vendor SN: AZ8P72890H23
Date code: 070709
Diag Monitoring Type:-Address change required: 0x0
-Power Measurement: 0x1
-Externally Calibrated: 0x0
-Internally Calibrated: 0x1
-Digital diag monitoring: 0x1
-Legacy diagnostic: 0x0
Enhanced Options:-Soft RATE_SELECT ctrl & monitoring: 0x0
-Soft RX_LOS monitoring: 0x1
-Soft TX_FAULT monitoring: 0x1
-Soft TX_DISABLE ctrl & monitoring: 0x0
-Alarm/warning flags: 0x1
SFF-8472 Compliance: TBD
CC_EXT: 0x26
Vendor Specific: 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff
0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff
0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff
0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff
Address A2
Temp High Alarm: 0x5f00
Temp Low Alarm: 0xf601
Temp High Warning: 0x5500
Temp Low Warning: 0xfb01
Voltage High Alarm: 0x8dcc
Voltage Low Alarm: 0x7404
Voltage High Warning: 0x8b10
Voltage Low Warning: 0x76c0
Bias High Alarm: 0x1194
Bias Low Alarm: 0x03e8
Bias High Warning: 0x109a
Bias Low Warning: 0x03e8
TX Signal Power High Alarm: 0x1a68
TX Signal Power Low Alarm: 0x03e8
TX Signal Power High Warning: 0x1938
TX Signal Power Low Warning: 0x0746
RX Signal Power High Alarm: 0x2710
RX Signal Power Low Alarm: 0x00fb
RX Signal Power High Warning: 0x1ba7
RX Signal Power Low Warning: 0x01f5
Rx_PWR(4): 0x00000000
Rx_PWR(3): 0x00000000
Rx_PWR(2): 0x00000000
Rx_PWR(1): 0x00000000
Rx_PWR(0): 0x00000000
Tx_I(Slope): 0x0000