Q-Logic FC HBA CLI Network Card User Manual


 
5 – Non-interactive Commands
Command Summary
5-18 SN0054614-00 F
S
Sections 5.3.16.1 through 5.3.16.5 describe how to change the default
parameters for both of these tests. Section 5.3.16.6 contains command line
examples and test results for a loopback test. Section 5.3.18.1 contains command
line examples and test results for a read/write buffer test.
5.3.16.1
DataPattern (DP)
For the loopback test, the data pattern is either:
DP <Parameter Value>
DataPattern <Parameter Value>
The data pattern must be in a two-character hexadecimal pattern in the range
of 00–FF. The hexadecimal letters can be uppercase or lowercase. The default
pattern is random, for example:
# scli -kl(<HBA Instance> | <HBA WWPN>) DP Random
To enter a customized value (in the range of 00–FF), type:
# scli -kl (<HBA Instance> | <HBA WWPN>) DP <Parameter Value>
In addition to a hex pattern, you can enter a compliant random data pattern
(CRPAT), jitter tolerance pattern (CJTPAT), or supply noise test sequence
(CSPAT) for a loopback test. For example:
# scli -kl (<HBA Instance> | <HBA WWPN>) DP CJTPAT
Table 5-5 lists all valid data patterns:
Parameter Name = One of the following:
DataPattern (see 5.3.16.1)
DataSize (see 5.3.16.2)
TestCount (see 5.3.16.3)
TestIncrement (see 5.3.16.4)
OnError (see 5.3.16.5)
Parameter Alias = One of the following:
DP (see 5.3.16.1)
DS (see 5.3.16.2)
TC (see 5.3.16.3)
TI (see 5.3.16.4)
OE (see 5.3.16.5)
Parameter Value = Value for selected parameter