Q-Logic FC HBA CLI Network Card User Manual


 
5 – Non-interactive Commands
Command Summary
5-20 SN0054614-00 F
S
Loopback test (Linux systems). The data size can be 8, 16, 32, 64, 128,
256, 512, 1024, 2048, 4096, 8192, 16384, 32768, or 65535. The default
value is 512 bytes.
5.3.16.3
TestCount (TC)
The number of loopback tests is either:
TC <Parameter Value>
TestCount <Parameter Value>
For a read/write buffer test, the number of tests run must be in the range of
0–10000.
For a loopback test, the number of tests run must be in the range of 0–65535.
For both tests, a value of 0 indicates that the test runs continuously (it stops when
you press ENTER). The default number of tests run is 500.
5.3.16.4
Test Increment (TI)
The Test Increment for the loopback test is either of the following:
TI <Parameter Value>
Test Increment <Parameter Value>
For a read/write buffer test, the test increment must be in the range of 1–10000.
For a loopback test, the test increment must be in the range of 1–65535.
If the number of tests is continuous (see section 5.3.16.3), the test increment is
automatically set to one of the following:
12 (Windows)
25 (Solaris)
2 (Linux and Macintosh)
The default test increment is 1. The test increment cannot be larger than the
number of tests run (see section 5.3.16.3).
5.3.16.5
OnError (OE)
For the loopback test, OnError is either:
OE <Parameter Value>
OnError <Parameter Value>
This parameter determines how errors are handled. Table 5-6 lists the valid
values.