Q-Logic FC HBA CLI Network Card User Manual


 
5 – Non-interactive Commands
Command Summary
SN0054614-00 F 5-23
A
Error – CRC, disparity, or frame length errors occurred.
Failed – An error occurred when attempting to issue a command.
Loop down – The loop is down.
CRC – Number of CRC errors.
Disparity – Number of disparity errors.
Frame Length – Number of frame length errors.
-kl
(<HBA Instance> | <HBA WWPN>) [{(<Parameter Name> |
<Parameter Alias>) <Parameter Value>}]
5.3.17
-kl
(Run HBA Diagnostics Loopback Test)
The <Parameter Name>, <Parameter Alias>, and <Parameter Value> options are
described in Table 5-8.
The system shows the following information after a loopback test completes:
Test status
CRC error
Disparity error
Frame length error
5.3.18
-kr
(Run Read/Write Buffer Test)
Use the -kr command to do read/write buffer test. (To run the loopback test, use
the -kl command—see section 5.3.16.)
To do a read/write test using the default parameters, type:
# scli -kr (<HBA Instance> | <HBA WWPN>)
To do a read/write test with customized parameters, type:
# scli -kr (<HBA Instance> | <HBA WWPN>) [(-EX | -EXCLUDE)
<Target WWPN>] (<Parameter Name> | <Parameter Alias>)
<Parameter Value>
NOTE:
Under Solaris, this feature is disabled if you are using the driver from the OS
installation CDs (QLC driver).