Fujitsu M10-4 Server User Manual


 
XSCF>
showlogs error
Note -
When you add or remove CPU memory units, confirm that no error has occurred.
XSCF>
replacefru
Note -
In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
Note -
When the CPU memory unit lower is replaced, all of the XSCF setting information
may be lost. Perform this operation only after backing up the XSCF setting information.
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Pow er off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to releas e the chassis requiring m aint ena nce
from th e system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7.
Remove all the po w er cords from the P SU backplane unit of the chassis
requiring mai nten ance.
For details, see "5.5.2 Removing the power cord."
7.3.3 System-stopped maintenance
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the dump co nfig command t o backup t h e XSCF setting information
only when r eplacing the C PU memory u nit lower i n a singe-ch assis
configuration.
For details, see "10.9.2 Saving XSCF setting information" in the Fujitsu
M10/SPARC M10 Systems System Operation and Administration Guide.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 201390