XSCF>
showboards -a
PSB PPAR-ID(LSB) Assignment Pwr Conn Conf Test Fault
---- ------------ ----------- ---- ---- ---- ------- --------
00-000(00) AssignedyyyPassedNormal
01-000(01) AssignednnnPassedDegraded
02-000(02) AssignedyyyPassedNormal
03-000(03) AssignednnnPassedFaulted
XSCF>
switchscf -t Standby
The XSCF unit switch between the Master and Standby states.
Continue? [y|n] :
y
XSCF>
showpparstatus -p 0
PPAR-ID PPAR Status
00 Running
5.3 Powering Off the Physical Partition
Requiring Maintenance
This section describes the procedure for powering off the physical partition requiring
maintenance. This is applicable if the system has a building block configuration and
has multiple physical partitions.
1.
Log in to the XSCF s hell.
2.
When the chas sis requiring maintenance is operating a s the m aster chassis,
execute the switchscf co m mand to switch the master XSCF to a st andb y
XSCF.
In response to the confirmation message, enter "y".
When the chassis requiring maintenance is a slave XSCF, proceed to step 4.
3.
Log in to the master XSCF a gain.
4.
Execute the sho w pp arstatus command t o confirm the operating co n dition of
the physical partition.
In the following example, [PPAR Status] of PPAR-ID 00 displays "Running",
which indicates that the physical partition is operating.
5.
Execute the sho w do mainstatus command to confirm the operating con dition
of th e logical d omain.
In the following example, [Status] of the logical domain displays "Solaris
running", which indicates that Oracle Solaris is operating.