Fujitsu M10-4 Server User Manual


 
Note -
Reinstall the fan units in their original positions by referring to the notes you made
prior to the start of maintenance.
Note -
Check that the front cover is firmly attached and secured.
Note -
If no crossbar unit is mounted, proceed to step 11.
Note -
Reinstall the PCIe card cassettes in their original positions by referring to the notes
that you made prior to the start of maintenance.
15.5.2 Restoring the chassis
1.
Connect the cables to the operation panel.
2.
Reinstall th e PSU b a ckplane unit in its original position and then tighten the
two screws.
3.
Reinstall th e fan shelf and t hen tighten the two screw s in the fan slot.
4.
Reinstall the power supply unit in its origina l position.
For details, see "10.5.1 Installing a power supply unit."
5.
Install all the fan units.
For details, see "11.5.1 Installing a fan unit."
6.
Install the front cover.
For details, see "6.5.3 Installing the front cover."
7.
Insert th e CPU memory unit i nto the c ha ssis.
8.
Raise the ri ght and left levers of the C P U memory u nit and then tighten the
one screw.
9.
Install the mounting fr ame for the crossbar un it and then tighten th e three
screws.
10.
Install all the crossbar units.
For details, see "9.5.1 Installing a crossbar unit."
11.
Install all the PCIe card cassettes.
For details, see "13.6.2 Installing a PCI Express card cassette."
12.
Connect all the cables to the external interface.
Thecablestobeconnectedareasfollows.
Interface cable connected to the PCIe card
Crossbar cable
XSCF BB control cable
XSCF DUAL control cable
Chapter 15 Maintaining the Operation Panel 291