#
cfgadm -c unconfigure
Ap_ID
#
cfgadm -x led=fault,mode=blin k
Ap_ID
#
cfgadm -a
Note -
Use the DR of the system board on a physical partition for active/cold maintenance.
For the XCP and Oracle VM Server for SPARC/SRU versions that correspond to the DR, see
the latest Product Notes.
Note -
Active/cold maintenance can be performed only for a building block configuration.
XSCF>
showlogs error
XSCF>
replacefru
6.
Execute the cfgadm(1M) command to blink t he CHECK LED of the internal
disk requiring maintenance, and d etermine its location.
Enter the Ap_ID you noted in advance.
7.
Execute the cfgadm(1 M) command to confirm t h at the internal disk requiring
maintenance is disconnected.
The disconnected internal disk is displayed as "unconfigured."
12.3.2 Active/Cold maintenance
1.
Open the r ack d oor.
2.
LogintotheXSCFshell.
3.
Execute the sho w logs command to identify t he component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm t he hardware and s oftw are configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Release the cha ssis, i n which the internal disk requiring maintenance is
mounted, f rom the p hy sical partition.
For details, see "5.2 Releasing a Chassis from the Physical Partition."
6.
Execute the replacefru command to release the chassis requiring m aintenance
from t he system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
Chapter 12 Maintaining the Internal Disks 229