Note -
When mounting a CPU memory unit, check the connectors on both of the
chassis and CPU memory unit beforehand to confirm that no pin is bent and all the
pinsareneatlyarrangedinlines.Ifthereisabentpininaconnector,mountinga
CPU memory unit may damage the chassis or CPU memory unit. Also, carefully
proceed with the work to prevent any pin from being bent.
Note -
A part of the procedure varies depending on the CPU memory unit type. To
determine the CPU memory unit type, check the label in Figure 7-2.
Figure 7-43
Removing the PCIe cables (with the connector for one PCIe cable
facing the outside and the other two facing the front of the CPU
memory unit)
7.5 Installing a CPU Memory Unit
This section describes the procedure for installing a CPU memory unit.
Unless otherwise specified, the figures explained in this section use the SPARC
M10-4S with a FRAME-A CPU memory unit.
7.5.1 Installing a PCI Express cable
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
・
December 2013124