Note -
See the procedure for system-stopped maintenance for inactive/cold maintenance in a
single-chassis configuration.
Note -
Use the DR of the system board on a physical partition for active/cold maintenance.
For the XCP and Oracle VM Server for SPARC/SRU versions that correspond to the DR, see
the latest Product Notes.
Note -
Active/cold maintenance can be performed only for a building block configuration.
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
8.6.2 Restoring the chassis
1.
Install the CPU m e mory unit
.
If you have installed the memory of the CPU memory unit upper, see "7.5.2
Installing the CPU memory unit upper."
If you have installed the memory of the CPU memory unit lower, see "7.5.2
Installing the CPU memory unit upper"and"7.5.3 Installing the CPU memory
unit lower."
2.
Restore t h e chassis.
For details, see "7.5.4 Restoring the chassis."
8.7 Restoring the System
This section describes the procedure for restoring the system after replacement,
addition, and removal of memory. The restoration procedure differs depending on
the maintenance type as follows:
■
Active/Cold maintenance
■
Inactive/Cold maintenance
■
System-stopped maintenance
8.7.1 Active/Cold maintenance
1.
Connect all the po wer c ords to the PSU backplane unit of t he chassis
requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2.
Return to the operation of the XSCF firmw are replacefru co mman d to confirm
Chapter 8 Maintaining the Memory 175