Note -
In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
Caution -
Before you handle any components, wear a wrist strap to ground any static
electricity. If you perform this procedure without a wrist strap, individual
components or the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
Note -
Record the positions of the cables before removing them to ensure that they are
reinstalled correctly.
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Pow er off all t he physical p artitions.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Remove all the po w er cords from the p o w er supply unit of the crossbar bo x
requiring mai nten ance.
For details, see "5.5.2 Removing the power cord."
20.4 Removing the XSCF Interface Unit
This section describes the procedure for removing an XSCF interface unit.
Enable the removal of the XSCF interface unit before attempting to remove it. For
details, see "20.3 Enabling the Removal of the XSCF Interface Unit."
1.
Remove all the XSCF BB control cables and XS CF DUAL control cables
connected to the XSCF interface unit.
2.
Loosen the tw o screws (A in the figure) of the XSCF interface unit and lo w er
the r ight and left levers to release th e XSCF interface unit.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
・
December 2013340