Fujitsu M10-4 Server User Manual


 
XSCF>
showlogs error
XSCF>
replacefru
Note -
In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
10.3.5 System-stopped maintenance
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Stop t h e entire system.
For details, see "5.4 Stopping the Entire System."
6.
Execute the replacefru command to releas e the chassis requiring m aint ena nce
from th e system.
For a single-chassis configuration, you do not have to release the chassis.
Proceed to step 7.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7.
Remove all the po w er cords from the P SU backplane unit of the chassis
requiring mai nten ance.
For details, see "5.5.2 Removing the power cord."
10.4 Removing a Power Supply Unit
This section describes the procedure for removing a power supply unit. Enable the
removal of the power supply unit before attempting to remove it. For details, see
"10.3 Enabling the Removal of a Power Supply Unit."
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013198