XSCF>
showlogs error
XSCF>
replacefru
Note -
In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
Caution -
Before you handle any components, wear a wrist strap to ground any static
electricity. If you perform this procedure without a wrist strap, individual
components or the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Pow er off all t he physical p artitions.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command t o release th e operation p anel requiring
maintenance from the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7.
Remove all the po w er cords from the p o w er supply unit of the crossbar bo x
requiring mai nten ance.
For details, see "5.5.2 Removing the power cord."
23.4 Removing the Operation Panel
This section describes the procedure for removing the operation panel.
Enable the removal of the operation panel before attempting to remove it. For details,
see "23.3 Enabling the Removal of the Operation Panel."
23.4.1 Accessing the operation panel
1.
Check t h e ID s w itch on the operation p anel and r ecord the BB-ID set for the
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
・
December 2013370