Fujitsu M10-4 Server User Manual


 
XSCF>
showlogs error
XSCF>
replacefru
Note -
In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Pow er off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
26.3.4 Inactive/Cold maintenance
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Pow er off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to releas e the chassis requiring m aint ena nce
from th e system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7.
Remove all the power c ords from the PSU backplane unit or po wer s upply
unit of the c h assis requiring mainten ance.
For details, see "5.5.2 Removing the power cord."
26.3.5 System-stopped maintenance
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013406