Fujitsu M10-4 Server User Manual


 
Caution -
To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
XSCF>
showlogs error
XSCF>
replacefru
24.2.3 Precautions for replacement
Note the following points when replacing a crossbar cable (electrical):
Replace crossbar cables (electrical) in pairs.
24.3 Enabling the Removal of a Crossbar
Cable (Electrical)
This section describes the preparations that must be completed prior to removing the
crossbar cables (electrical). The preparation procedure differs depending on the
maintenance type as follows:
Inactive/Cold maintenance
System-stopped maintenance
24.3.1 Inactive/Cold maintenance
1.
Open the r ack do or.
2.
Log in to the XSCF s hell.
3.
Execute the sho w log s command to identify th e component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm th e hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Pow er off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to releas e the chassis requiring m aint ena nce
from th e system.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013382