Table 3-1
Status of components (continued)
Display D escription
Deconfigured Due to the failure or degradation of another unit, the target unit and
components of its underlying layer has been degraded, though there
is no problem in them.
Maintenance Maintenance is being performed. The replacefru, addfru, or initbb
command is being executed.
XSCF>
ioxadm env -te PCIBOX#2008
Location Sensor Value Resolution Units
PCIBOX#2008 AIRFLOW 180.000 0.000 CHM
PCIBOX#2008 P_CONSUMPTION 68.000 0.000 W
PCIBOX#2008/PSU#0 FAN 3936.000 0.000 RPM
PCIBOX#2008/PSU#1 FAN 3584.000 0.000 RPM
PCIBOX#2008/FAN#0 FAN 3374.000 0.000 RPM
PCIBOX#2008/FAN#1 FAN 3374.000 0.000 RPM
PCIBOX#2008/FAN#2 FAN 3374.000 0.000 RPM
PCIBOX#2008/IOBT T_INTAKE 26.000 0.000 C
PCIBOX#2008/IOBT T_PART_NO0 31.500 0.000 C
PCIBOX#2008/IOBT T_PART_NO1 30.750 0.000 C
PCIBOX#2008/IOBT T_PART_NO2 31.500 0.000 C
PCIBOX#2008/IOBT V_12_0V 12.069 0.000 V
PCIBOX#2008/IOBT V_3_3_NO0 3.293 0.000 V
PCIBOX#2008/IOBT V_3_3_NO1 3.295 0.000 V
PCIBOX#2008/IOBT V_3_3_NO2 3.291 0.000 V
PCIBOX#2008/IOBT V_3_3_NO3 3.300 0.000 V
PCIBOX#2008/IOBT V_1_8V 1.804 0.000 V
PCIBOX#2008/IOBT V_0_9V 0.900 0.000 V
3.3.4 Checking the status of a PCI expansion unit
If a PCI expansion unit is connected, execute the ioxadm command from the XSCF
shell to check the status of the PCI expansion unit.
ioxadm command
Execute the ioxadm command to check the environmental conditions (temperature,
voltage, etc.) or LED indications for the PCI expansion unit.
1.
LogintotheXSCFshell.
2.
Execute the ioxadm command to chec k the environmental conditions of the
specified PCI expansion un it.
To specify a PCI expansion unit, enter the serial number of the PCI expansion
unit after determining it by executing the ioxadm list command.
The following example shows the environmental conditions for the PCIBOX#2008
"2008" are the last four digits of the serial number of the PCI expansion unit.