Fujitsu M10-4 Server User Manual


 
XSCF>
replacefru
XSCF>
showlogs error
XSCF>
replacefru
Note -
Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
before disconnecting them to ensure that they are reinstalled correctly.
XSCF>
showlogs error
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
27.3.2 Active/Cold maintenance
1.
Open the r ack d oor.
2.
LogintotheXSCFshell.
3.
Execute the sho w logs command to identify t he component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm t he hardware and s oftw are configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Execute the replacefru command to release the XSCF DUAL cont ro l cable
requiring maintenance from the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
6.
Remove all the power cords from the P SU backplane unit or po wer supply
unit of the c ha ssis requiring maintenance.
For details, see "5.5.2 Removing the power cord."
27.3.3 Inactive/Hot maintenance
1.
Open the r ack d oor.
2.
LogintotheXSCFshell.
3.
Execute the sho w logs command to identify t he component requiring
maintenance.
Chapter 27 Maintaining the XSCF DUAL Control Cables 417