Fujitsu M10-4 Server User Manual


 
XSCF>
replacefru
Note -
Inactive/cold maintenance can be performed only for a building block configuration.
The inactive/cold maintenance procedure for a single-chassis configuration is the same as
that for stopping the system.
XSCF>
showlogs error
XSCF>
replacefru
Note -
Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
before disconnecting them to ensure that they are reinstalled correctly.
5.
Power off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to release the power supply unit requiring
maintenance from the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
10.3.4 Inactive/Cold maintenance
1.
Open the r ack d oor.
2.
LogintotheXSCFshell.
3.
Execute the sho w logs command to identify t he component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm t he hardware and s oftw are configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Power off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to release the chassis requiring m aintenance
from t he system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7.
Remove all the power cords from the P SU backplane unit of the chassis
requiring maintenance.
For details, see "5.5.2 Removing the power cord."
Chapter 10 Maintaining the Power Supply Units 197