XSCF>
testsb -v -y -s 00-0
XSCF>
testsb -v -y -s 00-0
7.
Close t he rack d oor.
13.7.2 Active/Hot maintenance (with DR)
1.
Return t o the op eration of the XSCF firm w are replacefru command to confirm
that th e chassis has been incorporat ed into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2.
Execute the testsb command to confirm that th e PCIe card requiring
maintenance is recognized.
When you enter the "-y" option for the testsb command, the system automatically
answers "y" (yes) in response to an inquiry.
The following example shows the diagnosis of system board 00-0.
During the diagnosis processing, the show-devs command of OpenBoot PROM
is executed, and the result is displayed.
3.
Incorporate i nto the ph ysical partition t h e chassis in which the PCIe card
requiring mai nten ance is mo unted .
For details, see "6.2 Incorporating a Chassis into a Physical Partition."
4.
Close t he rack d oor.
13.7.3 Inactive/Hot maintenance
1.
Log in to the XSCF s hell.
2.
Execute the testsb command to confirm that th e PCIe card requiring
maintenance is recognized.
When you input optional "-y" for the testsb command, the system automatically
answers "y" (yes) in response to an inquiry.
The following example shows the diagnosis of system board 00-0.
3.
Pow er on the physical p artition requiring main t enan ce.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
4.
Close t he rack d oor.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
・
December 2013262