Fujitsu M10-4 Server User Manual


 
#
ldm list-io
NAME TYPE BUS DOMAIN STATUS
---- ---- --- ------ ------
PCIE0 BUS PCIE0 primary IOV
PCIE1 BUS PCIE1 primary IOV
PCIE2 BUS PCIE2 primary IOV
PCIE3 BUS PCIE3 primary IOV
PCIE8 BUS PCIE8 domain01 IOV
PCIE9 BUS PCIE9 domain01 IOV
PCIE10 BUS PCIE10 domain01 IOV
PCIE11 BUS PCIE11 domain01 IOV
/BB0/CMUL/NET0 PCIE PCIE0 primary OCC
/BB0/CMUL/SASHBA PCIE PCIE0 primary OCC
/BB0/PCI0 PCIE PCIE1 primary EMP
/BB0/PCI3 PCIE PCIE2 primary EMP
/BB0/PCI4 PCIE PCIE2 primary EMP
/BB0/PCI7 PCIE PCIE3 primary EMP
/BB0/PCI8 PCIE PCIE3 primary EMP
/BB1/CMUL/NET0 PCIE PCIE8 domain01 OCC
/BB1/CMUL/SASHBA PCIE PCIE8 domain01 OCC
/BB1/PCI0 PCIE PCIE9 domain01 EMP
/BB1/PCI3 PCIE PCIE10 domain01 EMP
/BB1/PCI4 PCIE PCIE10 domain01 EMP
/BB1/PCI7 PCIE PCIE11 domain01 EMP
/BB1/PCI8 PCIE PCIE11 domain01 EMP
#
ldm stop domain01
#
ldm rm-io PCIE8 domain01
#
ldm rm-io PCIE9 domain01
#
ldm rm-io PCIE10 domain01
#
ldm rm-io PCIE11 domain01
#
ldm list-io
NAME TYPE BUS DOMAIN STATUS
---- ---- --- ------ ------
PCIE0 BUS PCIE0 primary IOV
Values displayed under [DOMAIN] are "primary" or "domain01", which
indicates that they are assigned to the control domain or domain01.
10.
Delete all the I/O devices from t he domain t o which the I/O devices of the
system b o ard to b e deleted are assigned.
In the following example, domain01 is stopped and the PCIe root complexes that
are owned by domain01 and related to the system board to be deleted are
released.
11.
Execute the ldm list-io c o mman d again to check t h e usage s tatus of the I/O
devices.
The following example shows that the values displayed under [DOMAIN] for
PCIE8, PCIE9, PCIE10, and PCIE11, which were used by domain01, are deleted
and the I/O devices are released.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 201358