Fujitsu M10-4 Server User Manual


 
Note -
Make a note of the positions of the cables connected to the external interface before
disconnecting them to ensure that they are reinstalled correctly.
Note -
Make a note of the positions of the PCIe card cassettes before removing them to ensure
that they are reinstalled correctly.
Note -
If no crossbar unit is mounted, proceed to step 7.
15.4.1 Accessing the operation panel
1.
Check the ID switch on the operation panel an d record the BB-ID s et for the
chassis requiring maintenance.
2.
Lower the c able support.
For details, see "5.5.1 Lowering the cable support."
3.
Remove all the cable s connected t o the extern al interface.
The cables to be removed are as follows.
Interface cable connected to the PCI Express (PCIe) card
Crossbar cable
XSCF BB control cable
XSCF DUAL control cable
LAN cable
4.
Remove all PCIe card cassettes.
For details, see "13.5.2 Removing a PCI Express card cassette."
5.
Remove all the crossb ar units.
For details, see "9.4.2 Removing a crossbar unit."
6.
Loosen the three screws securing the mounting fra me of the crossbar u nit
and t h en remove the f ram e.
Chapter 15 Maintaining the Operation Panel 287