Caution -
Before you handle any components, wear a wrist strap to ground any static
electricity. If you perform this procedure without a wrist strap, individual
components or the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
Note -
The cables connected to the rear of the crossbar box are bundled together and fastened
to the right cable support with a hook-and-loop fastener. To remove the cables, first remove
the hook-and-loop fastener from the cable support.
Note -
Record the positions of the cables before removing them to ensure that they are
reinstalled correctly.
17.4 Removing the XSCF Unit
This section describes the procedure for removing the XSCF unit.
Enable the removal of the XSCF unit before attempting to remove it. For details, see
"17.3 Enabling the Removal of the XSCF Unit."
1.
Remove all the cables connected to the maintenance-target XS CF unit.
The cables to be removed are as follows.
■
Serial cable
■
LAN cable
■
USB device
2.
Loosen the two screws ( A in the figure) of the XSCF unit and lower the right
and l eft levers to release th e XSCF u nit.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
・
December 2013312