Fujitsu M10-4 Server User Manual


 
XSCF>
diagxbu -y -b 00 -t 01
XSCF>
diagxbu -y -b 00 -p 02
XSCF>
showlogs error
3.
Execute the diagxbu command t o d iagnose the c rossbar cables.
-
When the system board of the c h assis connected with the crossbar cab les
is not incorporated into th e physical p artition, o r when the incorporated
physical partition is powered off:
The example below specifies the following:
00: The BB-ID of the chassis to start the diagnosis
01: The BB-ID of the destination where the chassis to start the diagnosis is
connected (You can specify more than one of these.)
To specify multiple connection destination BB-IDs, enter a command like
"diagxbu -y -b 00 -t 01 -t 02".
-
When the system board of the c h assis connected with the crossbar cab les
is in corporated into the physical partition, and the p hysical partition is
powered on:
The example below specifies the following:
00: The BB-ID of the chassis to start the diagnosis
02: The PPAR-ID of the destination where the chassis to start the diagnosis is
connected (You can specify only one of these.)
4.
Execute the sho w logs command to confirm that the system is operating
normally.
For details, see "3.3.5 Checking log information."
5.
Power on a ll the physical partitions.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
6.
Close t h e rack d oor.
Chapter 21 Maintaining the Crossbar Backplane Unit of the Crossbar Box 355