Fujitsu M10-4 Server User Manual


 
Caution -
To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
Note -
Unless the system has a redundant configuration, data on the hard disk drive will be
lost. Thus, perform this operation only after backing up the data on the hard disk drive. In
addition, active/hot maintenance of the boot device cannot be performed in a non-redundant
configuration.
#
cfgadm -a
12.3.1 Active/Hot maintenance
Before performing maintenance, check the hardware configuration and software
configuration. For details, see "4.2 Confirming the System Configuration."
The procedure may vary depending on the configuration of the hard disk drive.
When the system is configured with a hardware RAID
Proceed only after checking the failed hard disk drive. For details, see "14.2.8
Checking the disk drive status" and "14.2.9 Checking for a failed disk drive" in the
Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide.
When the system is configured with a software RAID
See your software manual.
When the system is configured without either a hardware RAID or software
RAID
To add an internal disk, perform the procedure up to step 2.
1.
Open the r ack do or.
2.
Display th e Oracle S olaris super-user prompt.
3.
Execute the cfgadm(1 M) command to check th e configuration of the internal
disk.
If you replace or reduce an internal disk, use the cfgadm -a command to check
theAp_IDofthediskrequiringmaintenanceandmakeanoteofit.TheAp_ID
refers to a string such as "c4::dsk/c4t5000039428298FFEd0".
If you install an internal disk, use the cfgadm -a command to check the number
of disks mounted.
4.
Stop all ap plications from using the interna l disk.
5.
Execute the cfgadm(1 M) command to release the internal disk requiring
maintenance from the system.
Enter the Ap_ID you noted in advance.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013228