IBM 750GL Computer Accessories User Manual


 
User’s Manual
IBM PowerPC 750GX and 750GL RISC Microprocessor
Bus Interface Operation
Page 320 of 377
gx_08.fm.(1.2)
March 27, 2006
8.9 Using Data-Bus Write-Only
The 750GX supports split-transaction pipelined transactions. It supports a limited out-of-order capability for its
own pipelined transactions through the data-bus write-only (DBWO
) signal. When recognized on the clock of
a qualified DBG
, the assertion of DBWO directs the 750GX to perform the next pending data write tenure (if
any), even if a pending read tenure would have normally been performed because of address pipelining. The
DBWO
signal does not change the order of write tenures with respect to other write tenures from the same
750GX. It only allows a write tenure to be performed ahead of a pending read tenure from the same 750GX.
In general, an address tenure on the bus is followed strictly in order by its associated data tenure. Transac-
tions pipelined by the 750GX complete strictly in order. However, the 750GX can run bus transactions out of
order only when the external system allows the 750GX to perform a cache-line-snoop-push-out operation (or
other write transaction, if pending in the 750GX write queues) between the address and data tenures of a
read operation through the use of DBWO
. This effectively envelopes the write operation within the read oper-
ation. Figure 8-26 shows how the DBWO
signal is used to perform an enveloped write transaction.
Figure 8-25. IEEE 1149.1a-1993 Compliant Boundary-Scan Interface
Figure 8-26. Data-Bus Write-Only Transaction
TDI (Test Data Input)
TMS (Test Mode Select)
TCK (Test Clock Input)
TDO (Test Data Output)
TRST (Test Reset)
AACK
DBG
ABB
BG
(2) (1)
DBB
Enveloped Write
DBWO
Transaction
(1) (2)
Read Address
Write Address
Write Data Read Data