Dell M8024 Network Card User Manual


 
128 Configuring System Information
UDP Port (1
65535) —
Sets the UDP port from which the logs are sent. The default value is 514.
Facility —
A user-defined application from which system logs are sent to the remote server. Only one
facility can be assigned to a single server. If a second facility level is assigned, the first facility level is
overridden. All applications defined for a device use the same facility on a server. The possible field
values are from
Local 0
to
Local 7
.
Description
— Sets the server description. The maximum length is 64 characters.
Severity
— Selects the log severity. Selecting a severity level automatically selects all higher severity
levels.
Remove Log Server
— Removes a server from the
Log Server
list. Checking the check box removes the
server from the list. Leaving the box unchecked maintains the server in the list.
The Remote Log Server Settings
page also contains a severity list. The severity definitions are the same
as the severity definitions on the RAM Log Table page.
Sending Logs to a Server
1.
Open the
Remote Log Server Settings
page.
2.
Define the
UDP Port
,
Facility
, and
Description
fields.
3.
Select the log type and log severity by using the
Log Parameters
check boxes.
Note: When you select a severity level, all higher severity levels are automatically selected.
4.
Click
Apply Changes
.
The log settings are saved, and the device is updated.
Adding a New Server
1.
Open the
Remote Log Server Settings
page.
2.
Click
Add
to display the
Add Remote Log Server
page.
Note: Before adding a new server, determine the IP address of the remote log server.