XG2000 series User's Guide
238/315
All Rights Reserved, Copyright (C) PFU LIMITED 2009
5.18 RMON Setup Commands
This section explains the RMON configuration settings.
5.18.1 show rmon
Function
Displays the current RMON settings.
Prompt
xg> or xg#
Command syntax
show rmon
Command type
Operation management command
Output form
xg# show rmon
RMON Information 2007/01/22-06:03:09
===============================================================================
History Information
-------------------------------------------------------------------------------
[History 1]
Port
: port-1
Buckets : 10
Interval: 1800
Owner
: Administer
-------------------------------------------------------------------------------
Alarm Information
-------------------------------------------------------------------------------
[Alarm 1]
Monitored OID
: .1.3.6.1.2.1.16.1.1.1.7.1
Monitoring Interval: 10
Sample Type
: { Absolute | Delta }
Rising Threshold : 1000
Rising Event : 1
Falling Threshold
: 0
Falling Event : 0
Owner : Administer
-------------------------------------------------------------------------------
Event Information
-------------------------------------------------------------------------------
[Event 1]
Event Type
Log : { Enabled | Disabled }
Trap : { Enabled | Disabled }
Trap Community
: public
Description
: Traffic alarm event
Owner : Admin
===============================================================================
History Information
Displays the current RMON history settings.
z [History 1]
Indicates an index number that identifies the history group (historyControlTable).
z Port
Displays the port number for the collected RMON history group information.
z Buckets
Indicates the stored data unit count for the RMON history group.
z Interval
Indicates an interval (in seconds) for collecting the RMON history group data.
z Owner
Displays the owner name of the RMON history group.
Alarm Information
Displays the current RMON alarm settings.
z [Alarm 1]
Indicates a unique ID assigned to the RMON alarm.
z Monitored OID
Indicates an OID within the MIB object to be monitored.
z Monitoring Interval
Indicates an interval (in seconds) for threshold check of the MIB to be monitored.
z Sample Type
Displays the threshold evaluation method.
− Absolute
The value obtained from the MIB is evaluated based on the absolute value.
− Delta
The difference between the value obtained from the previous MIB and the value obtained
from the current MIB is evaluated.