Fujitsu XG2000 Switch User Manual


 
XG2000 series User's Guide
266/315
All Rights Reserved, Copyright (C) PFU LIMITED 2009
The following table provides descriptions of items displayed when the "show system status" command is entered and an
explanation of each error message.
Item Item displayed Message explanation/Solution
Temperature Displays the temperature inside the chassis.
Internal (internal temperature sensor) z good
The temperature is within normal operating range.
z caution
The temperature is high, but within normal operating range. The
system will be shutdown if it reaches the alarm threshold.
Check that the air vent is not blocked.
Check that the temperature of the switch location is
within the limits specified.
z Temperature is out of range. (xx yy)
The temperature is out of normal operating range. If the
temperature exceeds high alarm threshold, the system will be
shutdown.
Check that the air vent is not blocked.
Check that the temperature of the set up location is
within the limits set out by the operation guarantee.
If the same message is displayed after re-examining the set up of
the device, contact the sales representative.
Power Supply Display the status of power supply unit.
PWR - 0 (status of power supply unit 0) z good
The power supply unit 0 is properly installed and functional.
z Removed
The power supply unit 0 was removed. If this message appears with
the power supply unit 0 installed, check that the unit is properly
installed.
z Off Line
Power is not reaching the power supply unit 0. Check the AC inputs.
z Alarm Detected.
A power supply error was detected. Replace the unit.
PWR - 1 (status of power supply unit 1) Displays the status of power supply unit 1.The messages and
actions to take are the same as those described for power supply
unit 0.
Voltage Displays status of the CPU board supply voltages.
Voltage z Good
The voltage supplies are within normal operating range.
z VDP: Out of range. (xx)
A VDP voltage error was detected. Contact the sales
representative.
z VDE: Out of range. (xx)
A VDE voltage error was detected. Contact the sales
representative.
z VDR: Out of range. (xx)
A VDR voltage error was detected. Contact the sales
representative.
z VDD: Out of range. (xx)
A VDD voltage error was detected. Contact the sales
representative.
z VDN: Out of range. (xx)
A VDN voltage error was detected. Contact the sales
representative.
z 1.5V : Out of range. (xx)
A 1.5V power supply error was detected on the CPU board. Contact
the sales representative.
z 3.3V : Out of range. (xx)
A 3.3V power supply error was detected on the CPU board. Contact
the sales representative.
z 12V : Out of range. (xx)
A 12V power supply error was detected on the CPU board. Contact
the sales representative.
z 3.3V (I/F): Out of range. (xx)
A 3.3V power supply error was detected on the switch board.
Contact the sales representative.
z 12V (I/F): Out of range. (xx)
A 12V power supply error was detected on the switch board.
Contact the sales representative.