Fujitsu XG2000 Switch User Manual


 
XG2000 series User's Guide
81/315
All Rights Reserved, Copyright (C) PFU LIMITED 2009
5.4.13 reset
Function
Restarts the device.
Prompt
xg#
Command syntax
reset [ factory-default ]
Parameter
z [ factory-default ]
When this parameter is specified, the contents of startup-config, log, and login password
will be returned to the factory default.
Command type
Operation management commands
Note
z When the system is restarted without having saved the running-config to startup-config, the information set in
running-config will be lost.
z When the device is restarted, the telnet and SSH sessions will be disconnected. Reconnect after restart of the system
is complete.
Example
Restart the device using the "reset" command.
When the "reset" command is executed, the confirmation message is displayed.
xg# reset
Do you restart system? (y/n) : Confirmation message is displayed.
When "y" or "Y" is entered, the reboot process will be performed. When "n" or "N" is entered, the reboot process will be
cancelled.
5.4.14 system shutdown
Function
Stops the device system and prepares it for power off.
After executing this command and the STATUS-LED goes out, turn off the power to the device.
Prompt
xg#
Command syntax
system shutdown
Command type
Operation management commands
Note
z When power to the device is turned off without executing the system shutdown command, the maintenance
information will not be properly stored. Furthermore, if the power is turned off while data is being written to nonvolatile
memory, it may be corrupted, and the system might not restart correctly on powerup.
z When the system is shut down without saving running-config to startup-config, the information set in running-config will
be lost.
Example
When the "system shutdown" command is executed, the confirmation message is displayed.
xg# system shutdown
Do you shutdown system? (y/n) : Confirmation message is displayed.
When "y" or "Y" is entered, the system shutdown process will be performed. When "n" or "N" is entered, the system shutdown
process will be canceled.