5.20.10 boot-system
Function
Switches the firmware image to be used for the next system startup.
Use this command only if a problem occurred using new firmware.
Prompt
xg#
Command syntax
boot-system { 1 | 2 }
Parameter
z { 1 | 2 }
Specifies the number of the firmware partition to be used during the next system startup.
The applicable firmware version can be checked by the “show system information” command.
− 1
Uses firmware 1 for the next system startup.
− 2
Uses firmware 2 for the next system startup.
Command type
Operation management command
Message
% Attempted to change to invalid firmware. Command failed.
Explanation
The previous firmware update may not have completed successfully. The firmware partition
is unusable.
Solution
Update the firmware again.
If the error recurs, contact the sales representative.
% 1$ in SRAM is invalid.
Explanation
An inconsistency in non-volatile (SRAM) memory data was detected.
[[Inserted string]]%1$: Abnormal memory contents
Solution
"Restart the system using the “reset” command. Then, retry the firmware update.
If the error recurs, contact the sales representative.
Example
Change the firmware to be used for the next system startup using the “boot-system” command.
Check that the firmware information (Next Startup Firmware) to be used for the next system startup changed using the “show
system information” command.
xg# boot-system 1
xg# show system information
Firmware Information
Firmware[1] : E10L10 Z01 2007/01/23-18:42:52
Updated Time
: 2007/01/21-22:08:12
Firmware[2] : E10L11 Z01 2007/01/31-19:27:12
Updated Time
: 2007/01/31-19:57:53
Current Firmware : [2]
Next Startup Firmware: [1]