Message ID
Severity
Message/Explanation/Solution
S1960
ERROR
Too many DRAM SBE detected.(%1$)
Explanation
The software detected too many DRAM single bit errors. No more events will be logged.
z [[Inserted string]]%1$: Details about error
Solution
The device supports single bit ECC, so the error is corrected. But a failure may occur if the error happens again
after a system reset. Note this message and those displayed above and below it then contact the sales
representative. This message type may not be recorded in the log.
S1970
WARNING
DRAM SBE detected.
Explanation
The software detected DRAM single bit error.
Solution
The device supports single bit ECC, so the error is corrected.
A.2.3 swc (Layer 2 Basic Control: 2000-2999)
Message ID
Severity
Message/Explanation/Solution
S2103
ERROR
Output Queue MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
z [[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
S2104
ERROR
Disabling port %1$.
Explanation
A failure occurred on the switch chip communication port. The port was disabled.
z [[Inserted string]]%1$: Port number
Solution
Note the message contents and contact the sales representative.
S2105
ERROR
Tag Memory MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
z [[Inserted string]]%1$: Port number
Solution
Note the message contents and contact the sales representative.
S2106
ERROR
Input Buffer Tag Memory MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
z [[Inserted string]]%1$: Port number
Solution
Note the message contents and contact the sales representative.
S2107
ERROR
Too Many Input Queue Tag Memory MBE Errors. LOG Disabled.
Explanation
An uncorrectable error was repeatedly detected in the switch chip. Logging for this event is disabled.
Solution
Note the message contents and contact the sales representative.
S2110
ERROR
CM Buffer MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
z [[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.
S2111
ERROR
Drop Queue MBE detected. %1$
Explanation
An uncorrectable error was detected in the switch chip.
z [[Inserted string]]%1$: Supplementary code for the error
Solution
Note the message contents and contact the sales representative.