Example
Save the current system status data as a maintenance information file in non-volatile memory then check the logged status of
the maintenance information using the “show maintenance” command.
Transfer the maintenance information to the “host1” TFTP server by naming it as the “mainte_collected date and time” file.
Compare the file size of the maintenance information displayed on the screen to the size of the file stored on the TFTP server.
xg# save maintenance
xg# show maintenance
Maintenance Information 2007/01/22-20:58:17
==================================================
NO Type Occurred Time
--- -------------------------- -------------------
1 system dump 2007/01/22-18:21:23
2 system dump(dump switch)
2007/01/22-20:57:58
3 system dump(machine check) 2007/01/22-20:58:14
==================================================
xg# tftp put-maintenance host1
Total file size: 480711 (bytes)