XG2000 series User's Guide
282/315
All Rights Reserved, Copyright (C) PFU LIMITED 2009
Message ID
Severity
Message/Explanation/Solution
S0109
WARNING
%1$ Speed is below the Low Limit. (%2$ %3$)
Explanation
The speed of a fan is below limit.
z [[Inserted string]]%1$: Displays the location of the detected fan speed error.
Rear Fan-0: Rear fan 0
Rear Fan-1: Rear fan 1
PWR-0 Fan: Fan installed in power supply unit 0
PWR-1 Fan: Fan installed in power supply unit 1
z [[Inserted string]]%2$, %3$: Fan speed.
Solution
Replace the fan unit.
P0110
INFO
%1$ Speed is good.
Explanation
The speed of a fan returned to normal.
z [[Inserted string]]%1$: Identifies the fan whose normal speed was restored.
Rear Fan-0: Rear fan 0
Rear Fan-1: Rear fan 1
PWR-0 Fan: Fan installed in power supply unit 0
PWR-1 Fan: Fan installed in power supply unit 1
S0111
INFO
%1$ is Removed.
Explanation
A fan was removed.
z [[Inserted string]]%1$: Identifies the fan removed.
Rear Fan-0: Rear fan 0
Rear Fan-1: Rear fan 1
P0112
INFO
%1$ is Inserted.
Explanation
A fan was installed.
z [[Inserted string]]%1$: Identifies the fan installed.
Rear Fan-0: Rear fan 0
Rear Fan-1: Rear fan 1
P0113
INFO
port %1$ Plug-In.
Explanation
An XFP was installed.
z [[Inserted string]]%1$: The port number of the installed XFP
P0114
INFO
port %1$ Plug-Out.
Explanation
An XFP was removed.
z [[Inserted string]]%1$: The port number of the XFP removed
P0120
INFO
Fan Speed was changed into high speed.
Explanation
The fan speed changed from normal to high speed.
P0121
INFO
Fan Speed was changed into normal speed.
Explanation
The fan speed changed from high to normal speed.
S0122
ERROR
port %1$ PHY Alarm is detected. (%2$)
Explanation
An XFP alarm was detected. If a high temperature is detected, the device will shut down the XFP.
z [[Inserted string]]%1$: Number assigned to the port that detected the alarm.
z [[Inserted string]]%2$: Displays additional information on the alarm.
Solution
Check the XFP connection and temperature around the XFP.
If the same message is displayed after taking appropriate action, note the message contents and contact the
sales representative.
S0123
WARNING
port %1$ PHY Warning is detected. (%2$)
Explanation
An XFP warning was detected.
z [[Inserted string]]%1$: Number assigned to the port that detected the warning.
z [[Inserted string]]%2$: Displays additional information on the warning.
Solution
The XFP is still good, but a failure may occur if the condition persists. Check the XFP connection and
temperature around the XFP.
If the same message is displayed after taking appropriate action, note the message contents and contact the
sales representative.