A.2 List of Event Logs
This section provides an explanation of message contents and actions to take for the associated message ID and severity in
ascending numerical order. There is no solution provided for messages that do not required action.
A.2.1 env (Health Monitoring: 0-999)
Message ID
Severity
Message/Explanation/Solution
S0101
ERROR
%1$ Temperature is out of range. (%2$ %3$)
Explanation
The temperature is out range for normal operation.
z [[Inserted string]]%1$: Location of detected temperature error.
Internal: The temperature inside the chassis
z [[Inserted string]]%2$, %3$: Temperature value
Solution
Confirm the following checks on the device:
z Check that the air vent is not blocked.
z Check that the temperature of the switch environment is within the limits specified.
If there is no air vent blockage and the ambient temperature is within specifications, note the message contents
and contact the sales representative.
S0102
WARNING
PWR-%1$ ALARM is detected.
Explanation
A power supply error was detected.
z [[Inserted string]]%1$: Power supply unit number
Solution
Replace the power supply unit.
S0104
WARNING
PWR-%1$ is Off Line.
Explanation
AC power is not reaching one of the power supply units.
z [[Inserted string]]%1$: Power supply unit number
Solution
Check the AC cable and plugs.
P0105
INFO
PWR-%1$ is On Line.
Explanation
Power was restored to the power supply unit.
z [[Inserted string]]%1$: Power supply unit number
S0106
INFO
PWR-%1$ is Removed.
Explanation
The power supply unit was removed.
z [[Inserted string]]%1$: Power supply unit number
Solution
If this message is received at times other than during hot swap, check for proper installation.
P0107
INFO
PWR-%1$ is Inserted.
Explanation
A power supply unit was installed.
z [[Inserted string]]%1$: Power supply unit number
Solution
If this message is received at times other than during hot swap, check for proper installation.
S0108
ERROR
%1$ is out of range. (%2$)
Explanation
A supply voltage error was detected.
z [[Inserted string]]%1$: Displays the types of power supply fault(s) (VDP/VDE/VDR/VDD/VDN/3.3V
Main/12V/3.3V(IF)/12V(IF)).
z [[Inserted string]]%2$: Value that represents the power supply fault
Solution
Note the message contents and contact the sales representative.