Message ID
Severity
Message/Explanation/Solution
S7492
CRITICAL
A system-dump has been saved. Cause: machine check occurred (memory or bus data error).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the "tftp put-maintenance
" or "scp put-maintenance" command then take
note of the message content before contacting the sales representative.
S7493
CRITICAL
A system-dump has been saved. Cause: machine check occurred (bus timeout).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the "tftp put-maintenance
" or "scp put-maintenance" command then take
note of the message content before contacting the sales representative.
S7494
CRITICAL
A system-dump has been saved. Cause: machine check occurred (memory or bus data error,
bus timeout).
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the "tftp put-maintenance
" or "scp put-maintenance" command then take
note of the message content before contacting the sales representative.
S7495
CRITICAL
A system-dump has been saved. Cause: machine check occurred.
Explanation
A machine check error occurred and a system dump saved.
Solution
Obtain maintenance information using the "tftp put-maintenance
" or "scp put-maintenance" command then take
note of the message content before contacting the sales representative.
A.2.10 update (Firmware Update: 7500-7999)
Message ID
Severity
Message/Explanation/Solution
S7500
INFO
init-firmup: New firmware '%1$' is running.
Explanation
New updated firmware was initialized.
z [[Inserted string]]%1$: Firmware version information
S7501
INFO
init-firmup: Firmware '%1$' is running.
Explanation
New firmware was initialized after "boot" command was issued.
z [[Inserted string]]%1$: Firmware version information
S7520
WARNING
init-firmup: Booting new firmware failed. Old firmware '%1$' is now running.
Explanation
Old firmware was invoked because new updated firmware could not initialize.
z [[Inserted string]]%1$: Firmware version information
Solution
Reattempt the update process to boot the new updated firmware.
If the message is repeatedly displayed, contact the sales representative.
S7521
WARNING
init-firmup: Firmware update information is initialized for region %1$.
Explanation
The firmware information was initialized.
z [[Inserted string]]%1$: Firmware number
Solution
No action is required if this message appears in Step 2 of "Restoring Factory Defaults
".
If the message is displayed every time the system is booted, contact the sales representative.
S7530
CRITICAL
init-firmup: Internal error occurred (inconsistency in firmware update information).
Explanation
An error occurred while processing the firmware update information.
z [[Inserted string]]%1$: Firmware version information
Solution