9. Press F3 (Exit) until you obtain the display requesting that you press Enter to
continue ending SST.
Note: The trace does not stop if you exit SST while the trace is running.
10. Press the Enter key to exit SST.
11. Enter the following command to vary on the line:
VRYCFG CFGOBJ(line-name) CFGTYPE(*LIN)
STATUS(*ON)
Ensure that the interface associated with the line description is started. You
can use the STRTCPIFC command to start an interface.
12. Enter the commands and programs that caused the problem. Trace the data
on the line for a period of time specified by your service provider.
13. Go to “Stopping a Communications Trace” after the error occurs.
Stopping a Communications Trace
To stop the trace:
1. If you are at the Work with Communications Traces display, type a 2 in the Opt
column next to the name of the line you want to stop tracing.
Note: If the status is waiting, press F5 (Refresh) to refresh the status on the
Work with Communications Traces display.
2. Press the Enter key. In this example, the trace status changed to stopping. The
following display appears:
3. Press F5 (Refresh) to refresh the display. In this example, the trace status
changed to stopped. The following display appears:
Work with Communications Traces
Type options, press Enter.
2=Stop trace 4=Delete trace 6=Format and print trace
7=Display message 8=Restart trace
Configuration
Opt Object Type Trace Description Protocol Trace Status
TRNLINE LINE TCP/IP TRACE TRN STOPPING
F3=Exit F5=Refresh F6=Start trace F10=Change size
F11=Display buffer size F12=Cancel
498 OS/400 TCP/IP Configuration and Reference V4R4