Patton electronic 2616RC Switch User Manual


 
G.SHDSL Port Configuration window 111
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 9 • G.SHDSL (Model 3096RC)
remSerLoop(8)
remEthLoop(11)
Otherwise, display-only with a value of off(9).
Until the G.SHDSL link is established, the G.SHDSL Port Status table will display a dash (-) in the Test Pat-
tern column using display-only format. Once the G.SHDSL link is established and the port state changes to
datamode(1), the Test Pattern drop-down menu will appear.
The Test Pattern parameter defines which test pattern the T-DAC will generate and transmit. The T-DAC’s will
transmit the selected test pattern to the destination port defined by the value of Test Mode (see section “Test
Mode (sDSLTMSelection)” on page 108). To define the Test Pattern, select one of the following values from
the drop-down menu, then click the Submit button:
off(0)
ser511(1)
ser511E(2)
ser2047(3)
ser2047E(4)
ser63(5)
ser63E(6)
eth511(7)
eth511E(8)
eth2047(9)
eth2047E(10)
eth63(11)
eth63E(12)
Once you click the Submit button, the Test Pattern column will display the newly defined value in display-
only format, together with a check box labelled Off. To disable the test or to change the test pattern, click the
Off check box and click the Submit button.