Patton electronic 2616RC Switch User Manual


 
Defining a T1/E1 Management Channel 156
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 11 • In-band management
Example 1: T1/E1 Frame Relay Management Channel
Do the following to create a Frame Relay channel on T1/E1 port #1, timeslots 1–4:
Figure 86. Define a T1/E1 Management Channel window, frameRelay(3) function selected
1. Set the parameters as follows:
Port: port1(1)
Function: frameRelay(3)
–Timeslots: 14
2. Click the Define button.
Note
Since you are configuring the T1/E1 port for Frame Relay, the
timeslot will automatically be set to Frame Relay, even if the timeslots
were previously configured for PPP.
Figure 87. Defined In-Band Management Channels and Define a T1/E1 Management Channel sections
3. Click on T1/E1 under the Interface Type column in the table to view or modify the T1/E1 link parameters.
4. Click on Frame Relay under the Protocol Type to view the link’s status and HDLC statistics or modify the
DLMI and DLCI parameters.