Patton electronic 2616RC Switch User Manual


 
Far End Line Statistics—History 307
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 20 • T1/E1 Link
Line Errored Seconds (dsx1FarEndCurrentLESs)
The number of far-end line errored seconds encountered by a DS1 interface in the current 15-minute interval
Path Code Violations (dsx1FarEndCurrentPCVs)
The number of far-end path coding violations reported via the far-end block error count encountered by a
DS1 interface in the current 15-minute interval.
Bursty Errored Seconds (dsx1FarEndCurrentBESs)
The number of far-end bursty errored seconds (BESs) encountered by a DS1 interface in the current 15-
minute interval.
Degraded Minutes (dsx1FarEndCurrentDMs)
The number of far-end degraded minutes (DMs) encountered by a DS1 interface in the current 15-
minute interval.
Far End Line Statistics—History
Click on Far End Line Statistics—History to display far-end statistics for previously completed 15-minute inter-
vals (see figure 171).
Figure 171. History of Far End Performance window
Interval (dsx1FarEndIntervalNumber)
A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the least
recently completed 15-minutes interval (assuming that all 96 intervals are valid).