Patton electronic 2616RC Switch User Manual


 
CPE information and configuration 144
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 10 • iDSL (Model 3196RC)
Unavailable Time (idslUnavilSecond)—Total cumulative time in seconds (since the last power cycle) that
the link state for this port has been down.
CPE information and configuration
The Port Details page provides a window for CPE information and configuration. The CPE information win-
dow is only available for iDSL ports with active connections to remote CPEs.
Figure 77. CPE Information window
CPE information
The CPE information window (see figure 77) displays the following information for the remote device con-
nected to this iDSL port:
- Model code
- Software version
- Serial DTE rate
- Clock mode
- Test Mode indication
- Front panel switches
- DTE test mode
- User ID
CPE configuration
Some CPE configuration parameters can be modified from the T-DACS, these include Serial DTE Rate, Front
Panel Switches, DTE Test Mode, and the User ID.
To modify the CPE configuration, click on the Change Configuration button (see figure 77 on page 144).
This action will reveal drop down menus for CPE configurable parameters (see figure 78).