Patton electronic 2616RC Switch User Manual


 
iDSL Near End Performance Interval 145
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 10 • iDSL (Model 3196RC)
Figure 78. CPE configurable parameters window
Serial Rate—Select from the following:
- rate19-2k(0) for serial rate of 19200 bps
- rate32k(1) for serial rate of 32000 bps
- rate56k(1) for serial rate of 56000 bps
- rate64k(1) for serial rate of 64000 bps
- rate128k(1) for serial rate of 128000 bps
- rate144k(1) for serial rate of 144000 bps
Front Panel Switches—Front panel switches at the CPE can be enabled or disabled.
- dissabled(0)—CPE front panel switches disabled
- enabled(1)—CPE front panel switches enabled.
DTE Test Mode—CPE test mode can be enabled or disabled
- disabled(0)—CPE cannot initiate or respond to test patterns.
- enabled(1)—CPE can initiate or respond to test patterns
User ID—Enter new user ID for remote CPE
To activate changes made to this window, click on the Submit button. Otherwise, click on the Cancel button
to cancel changes.
iDSL Near End Performance Interval
For each of the T-DAC 16 iDSL ports, the T-DAC collects port error statistics in 15-minute intervals for the
most recent 24-hour period. The Port Details page displays port error statistics for the current 15 minute inter-
val this statistics include:
- Current Seconds
- Errored Seconds (ES)
- Severely Errored Seconds (SES)
- Unavailable Seconds (UAS)