Patton electronic 2616RC Switch User Manual


 
Near End Line Statistics—Totals 305
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 20 • T1/E1 Link
Near End Line Statistics—Totals
Click on Near End Line Statistics—Totals to display the total statistics of errors that occurred during the previ-
ous 24-hour period, the previous 96 15-minute intervals (see figure 169).
Figure 169. Totals of Near End Performance window
Errored Seconds (dsx1TotalESs)
The number of errored seconds encountered by a DS1 interface in the previous 24-hour interval.
Severely Errored Seconds (dsx1TotalSESs)
The number of severely errored seconds encountered by a DS1 interface in the previous 24-hour interval.
Severely Errored Frame Seconds (dsx1TotalSEFSs)
The number of severely errored framing seconds encountered by a DS1 interface in the previous 24-
hour interval.
Unavailable Seconds (dsx1TotalUASs)
The number of unavailable seconds encountered by a DS1 interface in the previous 24-hour interval.
Controlled Slip Seconds (dsx1TotalCSSs)
The number of controlled slip seconds encountered by a DS1 interface in the previous 24-hour interval.
Path Code Violations (dsx1TotalPCVs)
The number of path coding violations encountered by a DS1 interface in the previous 24-hour interval.
Line Errored Seconds (dsx1TotalLESs)
The number of line errored seconds encountered by a DS1 interface in the previous 24-hour interval.
Bursty ErroredSeconds (dsx1TotalBESs)
The number of bursty errored seconds (BESs) encountered by a DS1 interface in the previous 24-
hour interval.