T1/E1 port and DS0 selection 219
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 14 • PPP
Figure 120. WAN Circuit Configuration Link window
2. Click on Channel Assignment link (see figure 120) to access the WAN Circuit Channel Assignment window
(see figure 121). Options for the T1/E1 DS0s displayed on this page are:
– clear(9). The T/E1 DS0s carry user data (default)
– framerelay(3). The selected DS0(s) will carry management data using Frame Relay.
– ppp(5). The selected DS0(s) will carry management data using PPP
Figure 121. WAN Circuit Channel Assignment window displaying PPP configuration