Patton electronic 2616RC Switch User Manual


 
(WAN) Circuit ID # History of Near End Performance window 269
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 17 • System
Severely Errored Frame Seconds (dsx1IntervalSEFSs)
The number of severely errored framing seconds encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
Unavailable Seconds (dsx1IntervalUASs)
The number of unavailable seconds encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
Controlled Slip Seconds (dsx1IntervalCSSs)
The number of controlled slip seconds encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
Path Code Violations (dsx1IntervalPCVs)
The number of path coding violations encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
Line Errored Seconds (dsx1IntervalLESs)
The number of line errored seconds encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
Bursty Errored Seconds (dsx1IntervalBESs)
The number of bursty errored seconds (BESs) encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
Degraded Minutes (dsx1IntervalDMs)
The number of degraded minutes (DMs) encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
Line Code Violations (dsx1IntervalLCVs)
The number of line code violations (LCVs) encountered by a DS1 interface during the current 15-
minute interval.