Patton electronic 2616RC Switch User Manual


 
System Log Overview window 278
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 19 • System Log
Min Priority for Console RS-232 (syslogConsolePriority)
System messages which have a priority equal to or greater than this setting will be sent directly to the RS-232
Config control port (RJ-45 connector labeled “Config”) on the front panel of the T-DAC. Messages will be
sent regardless of the current operating state of the RS- 232 configuration port. The lower the number next to
the priority listed below, the more details system logging will provide. priorityVerbose will generate the most
messages, while priorityDisable will turn off all messages.
priorityVerbose(5)
priorityDebug(10)
priorityInfo(20)
priorityOddity(40)
priorityService(60)
prioritySystem(80)
priorityDisable(1000)
Min Priority for Flash Storage (syslogFlashPriority)
System messages which have a priority equal to or greater than this setting will be permanently stored in the
Flash PROM. Due to being permanent memory, the Flash memory eventually becomes filled. When this
occurs, the memory must be cleared before accepting more messages. Some maximum number of messages
may be stored in the Flash PROM before this storage area must be cleared.
prioritySystem(80)—Flash PROM will be used to store system-level messages.
priorityDisable(1000)—No messages will be stored.
Min Priority for SNMP Trap Daemon (syslogTrapPriority)
System messages which have a priority equal to or greater than this setting will be sent to the SNMP Trap Dae-
mon IP Address (syslogTrapIP). The lower the number next to the priority listed below, the more details sys-
tem logging will provide. Selecting priorityVerbose will generate the most messages, while selecting
priorityDisable will turn off all messages.
priorityVerbose(5)
priorityDebug(10)
priorityInfo(20)
priorityOddity(40)
priorityService(60)
prioritySystem(80)
priorityDisable(1000)