Operating status variables 41
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 2 • Home
– X denotes a major release involving an extensive system revision.
– Y indicates a revision within Release X adding one or more new features.
– Z denotes a revision within Release X.Y correcting problems that were found in the previous release.
– n (optional) is a lowercase alpha character. The value b for beta may indicate software made available to
certain parties for before the official formal release to the general public, often for early access trials or
field testing.
• Software release timestamp: The date and time the software version was created.
Operating status variables
The system variables that describe the operating status of the T-DAC are shown in figure 8 and described in
the following sections.
Figure 8. STATUS menu (Model 3096RC version shown)
Number of T1/E1 Ports (boxEgressCount)
Defines the number of T1/E1 WAN egress ports (4, 8, or 16) on the rear blade.
% CPU Idle (boxIdleTime)
Indicates the percent of system CPU capacity currently available to the T-DAC.
Running Since Last Boot (sysUpTime)
The time since the T-DAC was last power-cycled.
Chassis Address (cPCIShelfAddr)
Indicates the address of the ForeFront chassis in which the T-DAC resides. The address is set via DIP switches
located ForeFront chassis midplane. Using various On/Off combinations up to 33 (0–32) binary shelf
addresses can be defined. See ForeFront chassis User Guide for more information
Slot Address (cPCISlotID)
Indicates the ForeFront chassis slot number occupied by the T-DAC. On the ForeFront chassis models 6276
and 6476, slot numbering sequence starts from the bottom with slot number 1. Numbering sequence for the
ForeFront model 6676 starts from the left of the chassis with slot number 3.