Patton electronic 2616RC Switch User Manual


 
G.SHDSL Port Details window 117
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 9 • G.SHDSL (Model 3096RC)
Sync State (gshDSLSyncState)—Indicates the current state of synchronization on the line connecting this
G.SHDSL port and the remote CPE modem. One of the following values will be displayed:
- outOfSync(0)
- acquiringSync(64)
- inSync(128)
- losingSync(192)
Download Done (gshDSLDownloadDone)—Indicates whether the port’s DSP has loaded its operational
software from NVRAM. One of the following values will be displayed:
- yes(1)
- no(0)
Activation State Info table
The operating software for each G.SHDSL port includes a module called the Activation State Manager (ASM).
The Activation State Info table provides information about the current software state for the port. The current
values of the following G.SHDSL port parameters are shown in display-only format:
ASM State (gshDSLAtivationState)—Indicates the current state of the Activation State Manager (ASM).
One of the following values will be displayed:
- asm-Idle(0)
- asm-Normal(64)
- asm-Deactivated(128)
- asm-Training(192)
ASM Loss of Signal (gshDSLLossOfSignal)—Indicates whether or not the port currently detects the pres-
ence of the G.SHDSL signal. One of the following values will be displayed:
- loss(1)
- foundSignal(0)
PCM Clock (gshDSLActivationFailurInfo)—Indicates the current state of the pulse code modulation
(PCM) clock. One of the following values will be displayed:
- valid(0)—PCM clock is activated
- invalid(1)
Loss Of Sync Word—Indicates the current operating state of the ASM (gshDSLLossOfSyncWord)
G.SHDSL framing software for this port. The ASM framer uses the synch word field in the G.SHDSL
frame to control the timing on the link. One of the following values will be displayed:
- loss(4)—G.SHDSL timing is out of synchronization
- foundWord(0)—G.SHDSL timing is synchronized