![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/a1/ba16a712-7247-48c4-a96f-92634b6faf4f/ba16a712-7247-48c4-a96f-92634b6faf4f-bgfe.png)
T1/E1 Port Information table 254
Models 2616RC, 3096RC & 3196RC Admin Reference Guide 17 • System
Figure 139. T1/E1 port information
T1/E1 Port Information table
The T1/E1 Port Information table (see figure 139) displays status information in three categories:
• Configure—WAN port numbers are displayed as hyperlinks. Clicking link displays a WAN Circuit Config-
uration Link window for configuring a WAN port.
• Circuit ID—The name defined for the WAN circuit.
• Status—Shows the operating status of the WAN circuit.
Note
WAN port status color indicators show the state of each T1/E1 WAN
port.The status indication symbols (see figure 137 on page 252) are
defined as follows:
•
Green square—Functioning properly and no alarms are present.
•
Flashing red star—A critical (severity 4) alarm has been detected.
•
Orange exclamation mark—A major (severity 5) alarm has been
detected.
•
Yellow triangle—A minor (severity 6) alarm has been detected.
•
Blue square—The circuit is undergoing loopback diagnostics.
•
Gray circle—Unused; not activated. The port is not configured
for operation.
For full details on the WAN circuit parameters, refer to chapter 20, “T1/E1 Link” on page 285.